Clean air in the workshop
In many workshops, someone spends part of the day welding, soldering or grinding.
Local exhaust ventilation takes the fume away at the point where the work makes it, instead of leaving it to hang in the air that everyone nearby breathes. In Great Britain, the Health and Safety Executive (HSE) sets out what employers have to do. This page follows HSE's guidance.
How extraction works
Local exhaust ventilation (LEV) takes fume or dust away at the point where the work makes it. A system has a hood that captures the fume, ducting or hoses, and an extraction unit with a filter.
Some systems sit on the tool itself. HSE's videos show on-torch extraction capturing welding fume. HSE treats on-tool extraction as a form of LEV.
Choosing a system that works
HSE gives employers a short list of steps for getting LEV that works. It sets them out because many employers buy LEV that does not work. Sometimes it is the wrong type. Sometimes it was not installed or maintained properly.
- Work out which tasks cause exposure.
- Write down what the LEV needs to do, and get a reputable supplier to advise.
- Involve your employees in choosing or designing it.
- Make sure it is installed properly and works.
- Ask for airflow indicators, a user manual and a log book.
Airflow indicators are not a legal requirement. HSE's guidance recommends them, because they show the operator straight away when airflow drops.
Keeping it working
Employers must keep LEV working properly. They should also arrange a thorough examination and test at least every 14 months. The record of that test must be kept for at least five years. Information showing that the installed system gives adequate protection should be kept for the life of the equipment.
The test should be done by someone competent. HSE recommends a label on each hood showing the test record. For on-tool extraction, only the extraction unit needs the formal test. Staff check the hoods and hoses by eye as part of routine maintenance.
Why HSE expects extraction
HSE says all welding fume can cause lung cancer, including fume from mild steel. It issued a safety alert in February 2019, after international cancer researchers reclassified welding fume. The alert said general ventilation does not give enough control.
HSE now expects engineering controls, such as local exhaust ventilation, for all welding indoors. This applies however short the task. Where extraction alone is not enough, workers also need suitable respiratory protective equipment. For welding outdoors, HSE expects suitable respiratory protection to be provided.
Extraction also controls manganese, which is present in mild steel welding fume. HSE links manganese to symptoms similar to Parkinson's disease.
Welding fume comes under the Control of Substances Hazardous to Health Regulations 2002, known as COSHH. The duty covers specialist welders and staff who weld now and then, however small the amount.
Every employer has to carry out a COSHH risk assessment. Employers with five or more employees also have to record the significant findings. HSE has separate guidance on fume from rosin-based solder flux, which covers the types of extraction suited to soldering.
Useful links
- HSE: welding fume, protect your workers
- HSE safety alert: mild steel welding fume
- HSE: health risks from welding
- HSE: COSHH
- HSE: local exhaust ventilation
- HSE: LEV information for employers
- HSE: LEV frequently asked questions
- HSE INDG408: Clearing the air, a guide to buying and using LEV
- HSE INDG249: rosin-based solder flux fume